Alessandro Ruggiero
Alessandro Ruggiero
University of Salerno -IT- Department of Industrial Engineering-
Potvrđena adresa e-pošte na unisa.it - Početna stranica
NaslovCitiranoGodina
Advanced biomaterials in hip joint arthroplasty. A review on polymer and ceramics composites as alternative bearings
S Affatato, A Ruggiero, M Merola
Composites Part B: Engineering 83, 276-283, 2015
732015
Experimental Comparison on Tribological Pairs UHMWPE/TiAl6V4 Alloy, UHMWPE /AISI 316L Austenitic Stainless and UHMWPE /Al2O3 Ceramic, under Dry and Lubricated Conditions
A Ruggiero, R D'Amato, E Gòmez, M Merola
TRIBOLOGY INTERNATIONAL 96 (DOI: 10.1016/j.triboint.2015.12.041), 349-360, 2016
722016
Experimental analysis of tribological behaviour of UHMWPE against AISI 420C and against TiAl6V4 alloy under dry and lubricated conditions
A Ruggiero, R D’Amato, E Gòmez
Tribology International, 2015
672015
Approximate analytical model for the squeeze-film lubrication of the human ankle joint with synovial fluid filtrated by articular cartilage
A Ruggiero, E Gòmez, R D’Amato
Tribology letters 41 (2), 337-343, 2011
492011
Tribo-mechanical characterization of reinforced epoxy resin under dry and lubricated contact conditions
A Ruggiero, M Merola, P Carlone, VM Archodoulaki
Composites Part B: Engineering 79, 595-603, 2015
452015
Tribological characterization of vegetal lubricants: Comparative experimental investigation on Jatropha curcas L. oil, Rapeseed Methyl Ester oil, Hydrotreated Rapeseed oil
A Ruggiero, R D’Amato, M Merola, P Valašek, M Müller
Tribology International 109, 529-540, 2017
422017
Approximate Closed-Form Solution Of The Synovial Fluid Film Force In The Human Ankle Joint With Non Newtonian Lubricant
A Ruggiero, E Gómez, R D'Amato
Tribology International, 2012
382012
Exploitation of waste date seeds of Phoenix dactylifera in form of polymeric particle biocomposite: investigation on adhesion, cohesion and wear
A Ruggiero, P Valášek, M Müller
Composites Part B: Engineering 104, 9-16, 2016
342016
On the tribological behavior of retrieved hip femoral heads affected by metallic debris. A comparative investigation by stylus and optical profilometer for a new roughness …
M Merola, A Ruggiero, JS De Mattia, S Affatato
Measurement 90, 365-371, 2016
312016
Monitoring of focusing tube wear during abrasive waterjet (AWJ) cutting of AISI 309
P Hreha, A Radvanska, J Carach, D Lehocka, K Monkova, G Krolczyk, ...
Metalurgija 53 (4), 533-536, 2014
312014
Online Monitoring and Analysis of Hydroabrasive Cutting by Vibration
S Hloch, A Ruggiero
Advances in Mechanical Engineering 2013, 2013
262013
FEM analysis of metal on UHMWPE total hip prosthesis during normal walking cycle
A Ruggiero, S Affatato, M Merola, MC De Simone
Proceedings of the XXIII conference of the Italian Association of …, 2017
252017
Sound pressure measurement of orchestral instruments in the concert hall of a public school
A Ruggiero, MC De Simone, D Russo, D Guida
INTERNATIONAL JOURNAL OF CIRCUITS, SYSTEMS AND SIGNAL PROCESSING 10, 75-81, 2016
242016
Outlier Detection for the Evaluation of the Measurement Uncertainty of Environmental Acoustic Noise
C Liguori, A Paolillo, A Ruggiero, D Russo
IEEE Transactions on Instrumentation and Measurement 65 (2), 234-242, 2016
242016
Does metal transfer affect the tribological behaviour of femoral heads? Roughness and phase transformation analyses on retrieved zirconia and Biolox® delta composites
S Affatato, A Ruggiero, JS De Mattia, P Taddei
Composites Part B: Engineering, 2016
232016
On the roughness measurement on knee prostheses
SA Jaber, A Ruggiero, S Battaglia, S Affatato
International Journal of Artificial Organs 38 (1), 39-44, 2015
222015
Experimental description of strength and tribological characteristic of EFB oil palm fibres/epoxy composites with technologically undemanding preparation
P Valášek, A Ruggiero, M Müller
Composites Part B: Engineering 122, 79-88, 2017
212017
Acoustical Noise Study of a Factory: Indoor and Outdoor Simulations Integration Procedure
C Guarnaccia, J Quartieri, A Ruggiero
INTERNATIONAL JOURNAL OF MECHANICS 8, 298-306, 2014
212014
Does metal transfer differ on retrieved Biolox® Delta composites femoral heads? Surface investigation on three Biolox® generations from a biotribological point of …
S Affatato, A Ruggiero, M Merola, S Logozzo
Composites Part B: Engineering 113, 164-173, 2017
202017
Determining environmental noise measurement uncertainty in the context of the Italian legislative framework
A Ruggiero, D Russo, P Sommella
Measurement 93, 74-79, 2016
202016
Sustav trenutno ne može provesti ovu radnju. Pokušajte ponovo kasnije.
Članci 1–20