Prati
Marija Majer
Marija Majer
Doc. dr. sc. fizike, Institut Ruđer Bošković
Potvrđena adresa e-pošte na irb.hr
Naslov
Citirano
Citirano
Godina
Measurement of stray radiation within a scanning proton therapy facility: EURADOS WG9 intercomparison exercise of active dosimetry systems
J Farah, V Mares, M Romero‐Expósito, S Trinkl, C Domingo, V Dufek, ...
Medical physics 42 (5), 2572-2584, 2015
712015
Establishing the European diagnostic reference levels for interventional cardiology
T Siiskonen, O Ciraj-Bjelac, J Dabin, A Diklic, J Domienik-Andrzejewska, ...
Physica Medica 54, 42-48, 2018
452018
Dose distribution of secondary radiation in a water phantom for a proton pencil beam—EURADOS WG9 intercomparison exercise
L Stolarczyk, S Trinkl, M Romero-Expósito, N Mojżeszek, I Ambrozova, ...
Physics in Medicine & Biology 63 (8), 085017, 2018
432018
Out-of-field dose measurements for 3D conformal and intensity modulated radiotherapy of a paediatric brain tumour
M Majer, L Stolarczyk, M De Saint-Hubert, D Kabat, Ž Knežević, S Miljanić, ...
Radiation protection dosimetry 176 (3), 331-340, 2017
412017
Dose mapping of the panoramic 60Co gamma irradiation facility at the Ruđer Bošković Institute–Geant4 simulation and measurements
M Majer, M Roguljić, Ž Knežević, A Starodumov, D Ferenček, V Brigljević, ...
Applied radiation and isotopes 154, 108824, 2019
352019
Cooperative foraging expands dietary niche but does not offset intra-group competition for resources in social spiders
M Majer, C Holm, Y Lubin, T Bilde
Scientific reports 8 (1), 11828, 2018
332018
6He+ 9Be reactions at 16.8 MeV
M Majer, R Raabe, M Milin, C Angulo, J Cabrera, E Casarejos, JL Charvet, ...
The European Physical Journal A 43 (2), 153-158, 2010
272010
Measurement of maximum skin dose in interventional radiology and cardiology and challenges in the set-up of European alert thresholds
J Farah, A Trianni, E Carinou, O Ciraj-Bjelac, I Clairand, J Dabin, ...
Radiation protection dosimetry 164 (1-2), 138-142, 2015
252015
Out-of-field doses for scanning proton radiotherapy of shallowly located paediatric tumours—a comparison of range shifter and 3D printed compensator
A Wochnik, L Stolarczyk, I Ambrožová, M Davidkova, M De Saint-Hubert, ...
Physics in Medicine & Biology 66 (3), 035012, 2021
242021
Comparison of response of passive dosimetry systems in scanning proton radiotherapy—a study using paediatric anthropomorphic phantoms
Ž Knežević, I Ambrozova, C Domingo, M De Saint-Hubert, M Majer, ...
Radiation protection dosimetry 180 (1-4), 256-260, 2018
222018
Feasibility of setting up generic alert levels for maximum skin dose in fluoroscopically guided procedures
H Jarvinen, J Farah, T Siiskonen, O Ciraj-Bjelac, J Dabin, E Carinou, ...
Physica medica 46, 67-74, 2018
222018
Out-of-field doses in children treated for large arteriovenous malformations using hypofractionated gamma knife radiosurgery and intensity-modulated radiation therapy
M De Saint-Hubert, M Majer, H Hršak, Z Heinrich, Ž Knežević, S Miljanić, ...
Radiation protection dosimetry 181 (2), 100-110, 2018
192018
Out‐of‐field doses in pediatric craniospinal irradiations with 3D‐CRT, VMAT, and scanning proton radiotherapy: a phantom study
M Majer, I Ambrožová, M Davídková, M De Saint‐Hubert, M Kasabašić, ...
Medical physics 49 (4), 2672-2683, 2022
162022
Correction of measured Gamma-Knife output factors for angular dependence of diode detectors and PinPoint ionization chamber
H Hršak, M Majer, T Grego, J Bibić, Z Heinrich
Physica Medica 30 (8), 914-919, 2014
162014
Characterisation of grids of point detectors in maximum skin dose measurement in fluoroscopically-guided interventional procedures
J Dabin, A Negri, J Farah, O Ciraj-Bjelac, I Clairand, C De Angelis, ...
Physica medica 31 (8), 1112-1117, 2015
142015
Peripheral doses in children undergoing Gamma Knife radiosurgery and second cancer risk
S Miljanić, H Hršak, Ž Knežević, M Majer, Z Heinrich
Radiation measurements 55, 38-42, 2013
122013
Two-photon decay of K-shell vacancy states in heavy atoms
K Ilakovac, M Uroić, M Majer, S Pašić, B Vuković
Radiation Physics and Chemistry 75 (11), 1451-1460, 2006
122006
Investigations into the basic properties of different passive dosimetry systems used in environmental radiation monitoring in the aftermath of a nuclear or radiological event
Ž Knežević, M Majer, Z Baranowska, OC Bjelac, G Iurlaro, N Kržanović, ...
Radiation Measurements 146, 106615, 2021
102021
Effects of near-source photon scattering at the energy of 60keV
M Majer, M Budanec, G Jerbić-Zorc, S Pašić, M Uroić, B Vuković, ...
Nuclear Instruments and Methods in Physics Research Section A: Accelerators …, 2004
102004
Infrared spectroscopy of ion tracks in amorphous SiO2 and comparison to gamma irradiation induced changes
M Karlušić, M Škrabić, M Majer, M Buljan, VA Skuratov, HK Jung, ...
Journal of nuclear materials 514, 74-83, 2019
92019
Sustav trenutno ne može provesti ovu radnju. Pokušajte ponovo kasnije.
Članci 1–20