Follow
Ghassem Heidarinejad
Title
Cited by
Cited by
Year
Experimental investigation of two-stage indirect/direct evaporative cooling system in various climatic conditions
G Heidarinejad, M Bozorgmehr, S Delfani, J Esmaeelian
Building and Environment 44 (10), 2073-2079, 2009
2692009
Parameters optimization of a vertical ground heat exchanger based on response surface methodology
V Khalajzadeh, G Heidarinejad, J Srebric
Energy and Buildings 43 (6), 1288-1294, 2011
1152011
Investigation of a hybrid system of nocturnal radiative cooling and direct evaporative cooling
G Heidarinejad, MF Farahani, S Delfani
Building and Environment 45 (6), 1521-1528, 2010
1102010
A novel integrated system of ground heat exchanger and indirect evaporative cooler
V Khalajzadeh, M Farmahini-Farahani, G Heidarinejad
Energy and Buildings 49, 604-610, 2012
942012
Novel modeling of an indirect evaporative cooling system with cross-flow configuration
G Heidarinejad, S Moshari
Energy and Buildings 92, 351-362, 2015
912015
A two-stage system of nocturnal radiative and indirect evaporative cooling for conditions in Tehran
MF Farahani, G Heidarinejad, S Delfani
Energy and Buildings 42 (11), 2131-2138, 2010
862010
Feasibility of using various kinds of cooling systems in a multi-climates country
G Heidarinejad, M Heidarinejad, S Delfani, J Esmaeelian
Energy and Buildings 40 (10), 1946-1953, 2008
712008
Numerical analysis of droplet impact onto liquid film
H Shetabivash, F Ommi, G Heidarinejad
Physics of Fluids 26 (1), 012102, 2014
702014
Increasing effectiveness of evaporative cooling by pre-cooling using nocturnally stored water
M Farmahini-Farahani, G Heidarinejad
Applied Thermal Engineering 38, 117-123, 2012
702012
Prediction of thermal comfort, IAQ, and energy consumption in a dense occupancy environment with the under floor air distribution system
MH Fathollahzadeh, G Heidarinejad, H Pasdarshahri
Building and Environment 90, 96-104, 2015
682015
Performance analysis of a ground-assisted direct evaporative cooling air conditioner
G Heidarinejad, V Khalajzadeh, S Delfani
Building and Environment 45 (11), 2421-2429, 2010
652010
Numerical simulation of a thermally stratified shear layer using the vortex element method
AF Ghoniem, G Heidarinejad, A Krishnan
Journal of Computational Physics 79 (1), 135-166, 1988
601988
Potential of a desiccant-evaporative cooling system performance in a multi-climate country
G Heidarinejad, H Pasdarshahri
International Journal of Refrigeration 34 (5), 1251-1261, 2011
592011
The effects of operational conditions of the desiccant wheel on the performance of desiccant cooling cycles
G Heidarinejad, H Pasdarshahri
Energy and Buildings 42 (12), 2416-2423, 2010
532010
Numerical study of regenerative evaporative coolers for sub-wet bulb cooling with cross-and counter-flow configuration
S Moshari, G Heidarinejad
Applied Thermal Engineering 89, 669-683, 2015
522015
Numerical simulation of counter-flow wet-cooling towers
G Heidarinejad, M Karami, S Delfani
International Journal of refrigeration 32 (5), 996-1002, 2009
512009
Numerical investigation of wet-bulb effectiveness and water consumption in one-and two-stage indirect evaporative coolers
S Moshari, G Heidarinejad, A Fathipour
Energy conversion and management 108, 309-321, 2016
502016
Effects of return air vent height on energy consumption, thermal comfort conditions and indoor air quality in an under floor air distribution system
G Heidarinejad, MH Fathollahzadeh, H Pasdarshahri
Energy and Buildings 97, 155-161, 2015
482015
Numerical simulation of the dual effect of green roof thermal performance
G Heidarinejad, A Esmaili
Energy Conversion and Management 106, 1418-1425, 2015
422015
Numerical investigation of electro hydrodynamics (EHD) enhanced water evaporation using Large Eddy Simulation turbulent model
G Heidarinejad, R Babaei
Journal of Electrostatics 77, 76-87, 2015
362015
The system can't perform the operation now. Try again later.
Articles 1–20