Lightweight Bismuth Titanate (Bi4Ti3O12) Nanoparticle-Epoxy Composite for Advanced Lead-Free X-ray Radiation Shielding L Yu, PL Yap, A Santos, D Tran, D Losic ACS Applied Nano Materials 4 (7), 7471-7478, 2021 | 39 | 2021 |
Characterisation of a real-time fibre-coupled beryllium oxide (BeO) luminescence dosimeter in X-ray beams AMC Santos, M Mohammadi, J Asp, TM Monro, S Afshar Radiation measurements 53, 1-7, 2013 | 37 | 2013 |
Risk of second primary cancer after breast cancer treatment LG Marcu, A Santos, E Bezak European Journal of Cancer Care 23 (1), 51-64, 2014 | 36 | 2014 |
Risk estimation of second primary cancers after breast radiotherapy EB Alexandre M. C. Santos, Loredana G. Marcu, Chia M. Wong Acta Oncologica, 2016 | 32 | 2016 |
Investigation of a fibre-coupled beryllium oxide (BeO) ceramic luminescence dosimetry system AMC Santos, M Mohammadi, S Afshar Radiation measurements 70, 52-58, 2014 | 27 | 2014 |
Bismuth Oxide Films for X-ray shielding: Effects of particle size and structural morphology L Yu, ALC Pereira, DNH Tran, AMC Santos, D Losic Materials Chemistry and Physics 260, 124084, 2021 | 25 | 2021 |
Energy dependency of a water-equivalent fibre-coupled beryllium oxide (BeO) dosimetry system AMC Santos, M Mohammadi, S Afshar Radiation Measurements 73, 1-6, 2015 | 19 | 2015 |
Robust Volume Calculations of Tumors of Various Sizes. AP Peskin, K Kafadar, AM Santos, G Haemer IPCV, 3-9, 2009 | 18 | 2009 |
Application of optical photogrammetry in radiation oncology: HDR surface mold brachytherapy MJJ Douglass, AMC Santos Brachytherapy 18 (5), 689-700, 2019 | 17 | 2019 |
Evaluation of a real‐time BeO ceramic fiber‐coupled luminescence dosimetry system for dose verification of high dose rate brachytherapy AMC Santos, M Mohammadi, S Afshar V Medical Physics 42 (11), 6349-6356, 2015 | 17 | 2015 |
High-yield preparation of edge-functionalized and water dispersible few-layers of hexagonal boron nitride (hBN) by direct wet chemical exfoliation L Yu, PL Yap, DNH Tran, AMC Santos, D Losic Nanotechnology 32 (40), 405601, 2021 | 11 | 2021 |
Radiation dose calculation in 3D heterogeneous media using artificial neural networks J Keal, A Santos, S Penfold, M Douglass Medical Physics 48 (5), 2637-2645, 2021 | 11 | 2021 |
Evaluation of camera settings for photogrammetric reconstruction of humanoid phantoms for EBRT bolus and HDR surface brachytherapy applications CA Bridger, MJJ Douglass, PD Reich, AMC Santos Physical and Engineering Sciences in Medicine 44 (2), 457-471, 2021 | 10 | 2021 |
Will COVID-19 change the way we teach medical physics post pandemic? A Haworth, AL Fielding, S Marsh, P Rowshanfarzad, A Santos, P Metcalfe, ... Physical and engineering sciences in medicine 43, 735-738, 2020 | 9 | 2020 |
Lightweight polyester fabric with elastomeric bismuth titanate composite for high-performing lead-free X-ray shielding L Yu, PL Yap, AMC Santos, DNH Tran, D Losic Radiation Physics and Chemistry 205, 110726, 2023 | 7 | 2023 |
The role of hypofractionation in proton therapy A Santos, S Penfold, P Gorayski, H Le Cancers 14 (9), 2271, 2022 | 7 | 2022 |
A dosimetric comparison of CT-and photogrammetry-generated 3D printed HDR brachytherapy surface applicators CA Bridger, PD Reich, AM Caraça Santos, MJJ Douglass Physical and Engineering Sciences in Medicine 45 (1), 125-134, 2022 | 7 | 2022 |
Evaluation of a real-time optically stimulated luminescence beryllium oxide (BeO) fibre-coupled dosimetry system with a superficial 140 kVp X-ray beam AMC Santos, R Gowda, E Bezak, S Afshar Physica Medica 65, 167-171, 2019 | 7 | 2019 |
Robust estimation of censored mixture models AM Santos University of Colorado at Denver, 2011 | 7 | 2011 |
Estimating the second primary cancer risk due to proton therapy compared to hybrid IMRT for left sided breast cancer AMC Santos, A Kotsanis, L Cunningham, SN Penfold Acta Oncologica 60 (3), 300-304, 2021 | 6 | 2021 |