Prati
Michael Cree
Michael Cree
Associate Professor in Engineering, University of Waikato
Potvrđena adresa e-pošte na waikato.ac.nz
Naslov
Citirano
Citirano
Godina
Retinal vessel segmentation using the 2-D Gabor wavelet and supervised classification
JVB Soares, JJG Leandro, RM Cesar, HF Jelinek, MJ Cree
IEEE Transactions on medical Imaging 25 (9), 1214-1222, 2006
19472006
Retinal vessel segmentation using the 2-D Gabor wavelet and supervised classification
JVB Soares, JJG Leandro, RM Cesar, HF Jelinek, MJ Cree
IEEE Transactions on medical Imaging 25 (9), 1214-1222, 2006
19472006
Retinopathy online challenge: automatic detection of microaneurysms in digital color fundus photographs
M Niemeijer, B Van Ginneken, MJ Cree, A Mizutani, G Quellec, ...
IEEE transactions on medical imaging 29 (1), 185-195, 2009
6502009
Regularisation of neural networks by enforcing lipschitz continuity
H Gouk, E Frank, B Pfahringer, MJ Cree
Machine Learning 110 (2), 393-416, 2021
5052021
A comparison of computer based classification methods applied to the detection of microaneurysms in ophthalmic fluorescein angiograms
AJ Frame, PE Undrill, MJ Cree, JA Olson, KC McHardy, PF Sharp, ...
Computers in Biology and Medicine 28 (3), 225-238, 1998
3091998
A fully automated comparative microaneurysm digital detection system
MJ Cree, JA Olson, KC McHardy, PF Sharp, JV Forrester
Eye 11 (5), 622-628, 1997
2371997
Towards direct reconstruction from a gamma camera based on Compton scattering
MJ Cree, PJ Bones
IEEE transactions on medical imaging 13 (2), 398-407, 1994
1681994
Automated image detection of retinal pathology
HF Jelinek, MJ Cree
CRC Press, 2010
1402010
Separating true range measurements from multi-path and scattering interference in commercial range cameras
AA Dorrington, JP Godbaz, MJ Cree, AD Payne, LV Streeter
Three-Dimensional Imaging, Interaction, and Measurement 7864, 786404, 2011
1392011
Technical Foundation and Calibration Methods for Time-of-Flight Cameras
D Lefloch, R Nair, F Lenzen, H Schäfer, L Streeter, MJ Cree, R Koch, ...
Time-of-Flight and Depth Imaging. Sensors, Algorithms, and Applications, 3-24, 2013
1042013
Automated segmentation of retinal blood vessels and identification of proliferative diabetic retinopathy
HF Jelinek, MJ Cree, JJG Leandro, JVB Soares, RM Cesar, A Luckie
JOSA A 24 (5), 1448-1456, 2007
1032007
Microaneurysm detection in colour fundus images
L Streeter, MJ Cree
Image Vision Comput. New Zealand, 280-284, 2003
952003
An automated microaneurysm detector as a tool for identification of diabetic retinopathy in rural optometric practice
HJ Jelinek, MJ Cree, D Worsley, A Luckie, P Nixon
Clinical and Experimental Optometry 89 (5), 299-305, 2006
932006
Modelling single cell electroporation with bipolar pulse parameters and dynamic pore radii
S Talele, P Gaynor, MJ Cree, J Van Ekeran
Journal of Electrostatics 68 (3), 261-274, 2010
922010
Achieving sub-millimetre precision with a solid-state full-field heterodyning range imaging camera
AA Dorrington, MJ Cree, AD Payne, RM Conroy, DA Carnegie
Measurement Science and Technology 18 (9), 2809, 2007
892007
Application of lidar techniques to time-of-flight range imaging
R Whyte, L Streeter, MJ Cree, AA Dorrington
Applied optics 54 (33), 9654-9664, 2015
802015
Automated microaneurysm detection
MJ Cree, JA Olson, KC McHardy, JV Forrester, PF Sharp
Proceedings of 3rd IEEE International Conference on Image Processing 3, 699-702, 1996
801996
Closed-form inverses for the mixed pixel/multipath interference problem in AMCW lidar
JP Godbaz, MJ Cree, AA Dorrington
IS&T/SPIE Electronic Imaging, 829618-829618-15, 2012
792012
Multiple frequency range imaging to remove measurement ambiguity
AD Payne, APP Jongenelen, AA Dorrington, MJ Cree, DA Carnegie
682009
Development of retinal blood vessel segmentation methodology using wavelet transforms for assessment of diabetic retinopathy
DJ Cornforth, HJ Jelinek, JJG Leandro, JVB Soares, RM Cesar Jr, ...
662005
Sustav trenutno ne može provesti ovu radnju. Pokušajte ponovo kasnije.
Članci 1–20